37
Reference Manual
00809-0100-4697, Rev GA
Section 3: Configuration
November 2014
Configuration
FD_FAILED_MASK
FD_FAIL_MASK parameter will mask any of the failed conditions listed in FD_FAILED_MAP. A bit
on means the condition is masked out from alarming and will not be reported.
FD_FAILED_PRI
Designates the alerting priority of the FD_FAILED_ALM, see Table 3-4 on page 31. The default is
0 and the recommended value are between 8 and 15.
FD_FAILED_ACTIVE
FD_FAIL_ACTIVE parameter displays the active alarms is active that are being selected for this
category. Only the alarm with the highest priority will be displayed. This priority is not the same
as the FD_FAILED_PRI parameter described above. This priority is hard coded within the device
and is not user configurable.
FD_FAILED_ALM
FD_FAIL_ALM indicates a failure within a device which makes the device non-operational.
FD_FAIL_ALM parameter is used primarily to broadcast a change in the associated active
conditions, which are not masked, for this alarm category to a Host System.
FD OFFSPEC ALARMS
An offspec alarm indicates that the device or some part of the device needs maintenance soon,
if the condition is ignored the device will eventually fail. There are five parameters associated
with FD OFFSPEC ALARMS, they are described below.
FD_OFFSPEC_MAP
FD_OFFSPEC_MAP parameter maps conditions to be detected as active for FD_ OFFSPEC
_ALARM category. Thus the same condition may be active in all, some, or none of the 4 alarm
categories. Below is a list of the failures with the highest priority first.
Sensor 1 Failure 6
Sensor 2 Failure 7
Sensor 3 Failure 8
Sensor 4 Failure 9
Sensor 5 Failure 10
Sensor 6 Failure 11
Sensor 7 Failure 12
Sensor 8 Failure 13
Table 3-9. FD Offspec Alarms
Alarm Priority
CJC Degraded 1
Body Temperature Out of Range 2
Sensor 1 Degraded 3
Sensor 2 Degraded 4
Table 3-8. FD Failure Alarms
Alarm Priority
Vue de la page 44