Résumé du contenu

Page 1 - Smart Wireless Gateway 1420

Quick Start Guide00825-0200-4420, Rev FDMay 2015Smart Wireless Gateway 142000825-0200-4420_RevFD.fm Page 1 Thursday, May 7, 2015 8:26 AM

Page 2 - Contents

May 201510Quick Start GuideConfigure the Smart Wireless GatewayTo complete initial configuration for the gateway:1. Access the default web page for th

Page 3 - Wireless considerations

Quick Start Guide11May 2015Step 2: Physical installationPipe mountTools needed: 2-in. (51 mm) mounting pipe or mast Two 5/16-in. (7,9 mm) u-bolts su

Page 4 - General considerations

May 201512Quick Start GuideRemote antenna (optional)The remote antenna options provide flexibility for mounting the Gateway based on wireless connecti

Page 5 - Powering the gateway

Quick Start Guide13May 2015Figure 6. Installation of WL2/WN2 OptionInstallation of WL3/WL4 option (indoor to outdoor applications)1. Mount the antenn

Page 6 - Figure 3. 1420 PoE Jumpering

May 201514Quick Start GuideFigure 7. Installation of WL3/WL4 OptionNote: Weather proofing is required!The remote mount antenna kit includes coaxial s

Page 7 - Establishing a connection

Quick Start Guide15May 2015NoteThe coaxial cables on the remote antenna options WL3 and WL4 are interchangeable for installation convenience.Table 3.

Page 8

May 201516Quick Start GuideStep 3: Connect to the host system1. Wire the Gateway’s Ethernet 1 (Primary) or Serial Output connection to the Host System

Page 9

Quick Start Guide17May 2015Twisted shielded pair cable is generally used to wire the Serial connection, and it is standard practice to ground the shie

Page 10 - Quick Start Guide

May 201518Quick Start GuideStep 5: Verify operationsOperation is verified through the web interface by opening a web browser from any PC on the host s

Page 11 - Pipe mount

Quick Start Guide19May 2015Product specificationsInput power10.5 – 30 VDC (must be a Class 2 power supply)Current drawOperating current draw is based

Page 12 - Remote antenna (optional)

May 20152Quick Start GuideNOTICEThis guide provides basic guidelines for the Smart Wireless Gateway. It does not provide instructions for diagnostics,

Page 13

May 201520Quick Start GuideEnvironmentalOperating temperature range-40 to 140 °F (-40 to 70 °C)Operating humidity range10-90% relative humidityPhysica

Page 14

Quick Start Guide21May 2015Ethernet10/1000base- TXEthernet communication portProtocols: Ethernet/IP ModbusTCP, OPC, HART-IP, HTTPS (for Web Interface)

Page 15

May 201522Quick Start GuideProduct CertificationsRev 1.1European Directive InformationA copy of the EC Declaration of Conformity can be found at the e

Page 16 - Best practice

Quick Start Guide23May 2015CanadaN6 Canada Division 2Certificate: CSA 70010780Standards: CAN/CSA C22.2 No. 0-M91 (R2001), CAN/CSA Std C22.2 No. 94-M9

Page 17

May 201524Quick Start GuideSpecial Condition for Safe Use (X):1. The surface resistivity of the antenna is greater than 1GΩ. To avoid electrostatic ch

Page 18 - Step 5: Verify operations

Quick Start Guide25May 2015Figure 12. EC Declaration of Conformity for Smart Wireless Gateway00825-0200-4420_RevFD.fm Page 25 Thursday, May 7, 2015

Page 19 - Product specifications

May 201526Quick Start Guide00825-0200-4420_RevFD.fm Page 26 Thursday, May 7, 2015 8:26 AM

Page 20 - Communication specifications

Quick Start Guide27May 201500825-0200-4420_RevFD.fm Page 27 Thursday, May 7, 2015 8:26 AM

Page 21

Quick Start Guide00825-0200-4420, Rev FDMay 2015Global HeadquartersEmerson Process Management 6021 Innovation BlvdShakopee, MN 55379, USA+1 800 999 93

Page 22 - Product Certifications

Quick Start Guide3May 2015Wireless considerationsPower up sequenceThe Smart Wireless Gateway (Gateway) should be installed and functioning properly be

Page 23 - International

May 20154Quick Start GuideGeneral considerationsPC requirementsOperating system (optional software only) Microsoft® Windows™ XP Professional, Service

Page 24 - Combinations

Quick Start Guide5May 2015Step 1: Initial connection and configurationDeltaV™ readyIf the Gateway was ordered DeltaV Ready (Data Protocols Code 5), th

Page 25

May 20156Quick Start GuideNoteFigure 1 depicts the terminal block of legacy gateways prior to the introduction of PoE capabilities. Figure 2 shows the

Page 26

Quick Start Guide7May 2015NoteOnly one port and one mode of operation (PD or PSE) can be selected at a time; any other combination of jumpers is inval

Page 27

May 20158Quick Start Guidec. Select Internet Protocol (TCP/IP), then select the Properties button.NoteIf the PC/laptop is from another network, record

Page 28 - *00825-0200-4420*

Quick Start Guide9May 20153. Disable proxies.a. Open a standard web browser (Internet Explorer, Mozilla Firefox, or other).b. Navigate to Tools>Int